日本CKD電(dian)(dian)(dian)(dian)(dian)磁(ci)(ci)(ci)(ci)閥(fa)(fa)(fa)安裝(zhuang)(zhuang): 1、先要(yao)檢(jian)查電(dian)(dian)(dian)(dian)(dian)磁(ci)(ci)(ci)(ci)閥(fa)(fa)(fa)是(shi)否(fou)與選(xuan)型參數一致,比如電(dian)(dian)(dian)(dian)(dian)源(yuan)(yuan)(yuan)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)、介質(zhi)(zhi)壓(ya)(ya)(ya)力、壓(ya)(ya)(ya)差等,尤(you)其(qi)是(shi)電(dian)(dian)(dian)(dian)(dian)源(yuan)(yuan)(yuan),如果搞(gao)錯,就會(hui)燒壞線圈。電(dian)(dian)(dian)(dian)(dian)源(yuan)(yuan)(yuan)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)應(ying)(ying)(ying)滿足(zu)額(e)定(ding)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)波(bo)動(dong)范(fan)圍:交(jiao)流(liu)+10%~-15%,直(zhi)(zhi)流(liu)+10%~-10%,平時(shi)線圈組件(jian)不(bu)(bu)宜(yi)拆開。 2、一般電(dian)(dian)(dian)(dian)(dian)磁(ci)(ci)(ci)(ci)閥(fa)(fa)(fa)的(de)(de)(de)(de)電(dian)(dian)(dian)(dian)(dian)磁(ci)(ci)(ci)(ci)線圈部(bu)件(jian)應(ying)(ying)(ying)豎直(zhi)(zhi)向上(shang),豎直(zhi)(zhi)安裝(zhuang)(zhuang)在水(shui)平于地(di)面(mian)的(de)(de)(de)(de)管道,如果受空間限制(zhi)或工況要(yao)求必須按側(ce)立安裝(zhuang)(zhuang)的(de)(de)(de)(de),需(xu)在選(xuan)型訂貨時(shi)提出。否(fou)則可(ke)能(neng)造(zao)成(cheng)電(dian)(dian)(dian)(dian)(dian)磁(ci)(ci)(ci)(ci)閥(fa)(fa)(fa)不(bu)(bu)能(neng)正常工作(zuo)。 3、接(jie)管之前要(yao)對管道進行沖洗,把(ba)管道中的(de)(de)(de)(de)金屬粉末及密封材料殘(can)留(liu)物,銹(xiu)垢等清除(chu)。要(yao)注意介質(zhi)(zhi)的(de)(de)(de)(de)潔凈度,如果介質(zhi)(zhi)內(nei)混(hun)有(you)塵垢,雜質(zhi)(zhi)等妨礙電(dian)(dian)(dian)(dian)(dian)磁(ci)(ci)(ci)(ci)閥(fa)(fa)(fa)的(de)(de)(de)(de)正常工作(zuo),管道中應(ying)(ying)(ying)裝(zhuang)(zhuang)過濾(lv)器或濾(lv)網。 4、如果介質(zhi)(zhi)會(hui)起水(shui)錘現象,那么應(ying)(ying)(ying)該(gai)選(xuan)用(yong)具防水(shui)錘功能(neng)的(de)(de)(de)(de)電(dian)(dian)(dian)(dian)(dian)磁(ci)(ci)(ci)(ci)閥(fa)(fa)(fa)或采取相應(ying)(ying)(ying)的(de)(de)(de)(de)防范(fan)措施。 5、電(dian)(dian)(dian)(dian)(dian)磁(ci)(ci)(ci)(ci)閥(fa)(fa)(fa)前后應(ying)(ying)(ying)加手動(dong)切斷閥(fa)(fa)(fa),同時(shi)應(ying)(ying)(ying)設旁路(lu),便于電(dian)(dian)(dian)(dian)(dian)磁(ci)(ci)(ci)(ci)閥(fa)(fa)(fa)在故障(zhang)時(shi)維護(hu)。 6、電(dian)(dian)(dian)(dian)(dian)磁(ci)(ci)(ci)(ci)閥(fa)(fa)(fa)一般是(shi)定(ding)向的(de)(de)(de)(de),不(bu)(bu)可(ke)裝(zhuang)(zhuang)反,通常在閥(fa)(fa)(fa)體上(shang)用(yong)→指(zhi)出介質(zhi)(zhi)流(liu)動(dong)方向,安裝(zhuang)(zhuang)時(shi)要(yao)依照→指(zhi)示的(de)(de)(de)(de)方向安裝(zhuang)(zhuang)。不(bu)(bu)過在真(zhen)空管路(lu)或特殊情況下可(ke)以(yi)反裝(zhuang)(zhuang)。 7、蒸汽(qi)用(yong)電(dian)(dian)(dian)(dian)(dian)磁(ci)(ci)(ci)(ci)閥(fa)(fa)(fa)入口側(ce)應(ying)(ying)(ying)裝(zhuang)(zhuang)有(you)疏(shu)水(shui)閥(fa)(fa)(fa),該(gai)處接(jie)管應(ying)(ying)(ying)傾斜。
日本CKD電磁閥使用注意事項:
1、部分負荷或壓力不能超過其設計值。
2、除非進出口的零部件已經與管道連接,否則不帶壓力操作產品。
3、按照設計,零件不能在水下工作,所以要保證控制系統不會有水。
4、如果(guo)溫度低于5攝氏度,請務(wu)必防(fang)止設備(bei)結(jie)冰。